PE2340 Energy PDU – The PE2340 Energy PDU contains 40 AC outlets and is available in IEC or NEMA socket configurations

PE2340 Energy PDU – The PE2340 Energy PDU contains 40 AC outlets and is available in IEC or NEMA socket configurations

Marcas:

Datasheet, Manual e Outros

Datasheet, Manual e Outros

REF: PE2340 Categoria Tags: , , , ,
  • Descrição
  • Informação adicional
  • Features
  • Diagram
  • Specs

Descrição

The PE2340 Energy PDU contains 40 AC outlets and is available in IEC or NEMA socket configurations. The PE2340 Energy PDU features a space-saving 0U design that allows it to be mounted vertically on the outside of a rack, resulting in a more efficient use of space in the server room, while providing 40 AC outlets.
The PE2340 Energy PDU can be integrated into an installation with the EC2004 Energy Box*, allowing you to monitor the real-time current and environmental conditions of the Energy PDU from the front panel of the EC2004 at the rack, or via Web GUI remotely – making your server room efficiently green with ease.

* ATEN EC2004 Energy Box and energy management software – eco Sensors are available at www.aten.com.

Informação adicional

Modelos

PE2340

  • Space saving 0U rack mount design
  • IEC or NEMA outlet models
  • Real-time PDU current monitoring ** When used in conjunction with the EC2004 Energy Box

PE2340-Energy-Box--PDU-dg-org

Function PE2340B PE2340G
Electrical
Nominal Input Voltage 100 – 240 VAC 100 – 240 VAC
Maximum Input Current 30A(Max) 32A(Max)
Input Frequency 50-60 Hz 50-60 Hz
Input Connection NEMA L6-30P IEC 60309 32A
Input Power 6240 VA(Max) 7360 VA(Max)
Outlet Type Total: 40 x IEC320 C13
Bank1: Outlet 1 – 20; 20 x C13
Bank2: Outlet 21 – 40; 20 x C13
Total: 40 x IEC320 C13
Bank1: Outlet 1 – 20; 20 x C13
Bank2: Outlet 21 – 40; 20 x C13
Nominal Output Voltage 100 – 240 VAC 100 – 240 VAC
Maximum Output Current (Outlet) 15A(Max) 10A(Max)
Maximum Output Current (Bank) 15A(Max) 16A(Max)
Maximum Output Current (Total) 30A(Max) 32A(Max)
Breakers 2 x 16A UL489 Breaker 2 x 16A UL489 Breaker
Metering Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box) Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box)
Outlet Switching None None
Environment Sensor Ports 0 0
Metering Accuracy Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H) TBD TBD
Weight TBD TBD
Power Cord Length 1.6 m 1.6 m
Environmental
Temperature (Operating / Storage) 0–50°C / -20–60°C 0–40°C / -20–60°C
Humidity (Operating & Storage) 0–80% RH, Non-Condensing 0–80% RH, Non-Condensing
Compliance
EMC Verification FCC, Others by Request CE, Others by Request
Safety Verification By Request CE-LVD, Others by Request
  • * The specification and pictures are subject to change without notice.
  • * All trademarks and logos are the properties of their respective holders.